Degasser Tower
CO₂ stripping between cation and anion units
A degasser tower removes dissolved carbon dioxide from water by trickling it over packing against a rising stream of air from a blower. In a DM plant it sits between the cation and anion units, so the anion resin no longer has to remove CO₂ as carbonic acid.

Degasser Tower process
Stripping CO₂ cuts the caustic used for anion regeneration and raises the treated-water output between regenerations. Jyoti builds degasser towers in FRP or rubber-lined construction with a degassed-water sump and transfer pump.
Built by Jyoti, backed by Jyoti chemistry
Every unit is designed from your water analysis, fabricated at our Sachin GIDC and Kim (Karanj) facilities, and supported after commissioning with Jyoti treatment chemicals, audits and AMC.
Key features
- Reduces anion-resin load
- Lowers caustic consumption
- Corrosion-resistant construction
- Random packing for high contact area
- Low-energy blower
- Compact footprint
Applications
- DM plant CO₂ removal
- Boiler feed-water systems
- RO permeate pH and CO₂ correction
- Power and process utilities

Technical parameters
Typical construction and design ranges for a Jyoti Degasser Tower. Every plant is sized to your water.
| Parameter | Jyoti design |
|---|---|
| Construction | FRP / MSRL tower with packing support and distributor |
| Packing | Random plastic packing |
| Air supply | Centrifugal blower |
| Storage | Degassed-water sump with transfer pump |
Indicative values. Final design, capacity and guaranteed outlet quality are fixed after a treatability study of your water.
Is a degasser always needed in a DM plant?
Not always. It pays off when the raw water has high alkalinity, because more CO₂ forms after the cation unit. For low-alkalinity water a two-bed plant without degasser can be enough.
Works well with

DM Plant & Mixed Bed
High-purity water for critical industrial applications
View details →
Reverse Osmosis (RO) Plant
Membrane desalting for process, boiler-feed and recycled water
View details →Want the full product booklet?
All Jyoti systems, equipment and the 78-product chemical range in one document.
Get a quote for your plant
Tell us about your water source, effluent, capacity and site. An engineer reviews it and comes back with the right scheme.
- Share your detailsWater or effluent type, flow (KLD / m³/h) and location.
- Engineer reviewWe call to clarify, and suggest sampling or a treatability study where needed.
- ProposalYou receive a technical scheme and commercial offer.