Jyoti Hydrotech Pvt. Ltd.Engineering drawing · Circular DAF
Walkway & railingRotating skimmer carriageFlotation tankSludge box
0%
Dissolved air flotation

Drawing the plant

Jyoti Hydrotech · Innovation in water since 1993

Skip to content
Since 1993 · Innovation in WaterSachin GIDC, Surat
Wastewater Treatment · System 06 of 09

EDR – Effluent Direct Reuse System

Jyoti's compact smart-screen system for direct effluent reuse

EDR (Effluent Direct Reuse) is Jyoti Hydrotech's compact, high-tech smart-screen system for wastewater, described by the company as the first of its kind in India. It removes 80–90% of organic matter and colour with little primary treatment.

EDR performance on real effluent

Inlet vs outlet, as published by Jyoti Hydrotech. Each pair of bars is scaled to its own inlet value.

InletEDR outlet
CODmg/L
3,008 in
601 out
80%reduction
TSSmg/L
1,982 in
10 out
99.5%reduction
TurbidityNTU
780 in
1 out
99.9%reduction
TDSmg/L
588 in
454 out
22.8%reduction

TDS changes little because EDR targets organics, colour and solids; dissolved salts are removed later by RO where needed.

How it works

EDR – Effluent Direct Reuse process

Step 1Raw EffluentHigh colour, TSS, turbidity
Step 2Minimal PrimaryLight conditioning
Step 3EDR Smart ScreenAutomatic flow & recovery control
Step 4Reuse WaterLow COD, TSS, turbidity

The system automatically controls permeate flow, reject flow, recovery and pressure, and handles effluent with high colour, TSS and turbidity. It needs about one-third of the area of a conventional scheme and cuts sludge generation by 70–80%.

Built by Jyoti, backed by Jyoti chemistry

Every unit is designed from your water analysis, fabricated at our Sachin GIDC and Kim (Karanj) facilities, and supported after commissioning with Jyoti treatment chemicals, audits and AMC.

Key features

  • Removes 80–90% of organic matter and colour
  • Little primary treatment needed
  • Automatic control of permeate, reject, recovery and pressure
  • Handles high colour, TSS and turbidity
  • Reduces COD, TSS, turbidity and colour
  • Recovers over 90% of indigo colour
  • About one-third the area of a conventional system
  • Cuts sludge generation by 70–80%

Applications

  • Textile and denim (indigo) effluent
  • Pigment industry effluent
  • Dye and colour effluent
  • Space-constrained ETP upgrades
EDR – Effluent Direct Reuse
Specification

Technical parameters

Typical construction and design ranges for a Jyoti EDR – Effluent Direct Reuse. Every plant is sized to your water.

ParameterJyoti design
OperationFully automated
FootprintAbout one-third of a conventional system
Sludge70–80% lower generation
ManpowerLower than a conventional scheme

Indicative values. Final design, capacity and guaranteed outlet quality are fixed after a treatability study of your water.

FAQ

Questions buyers ask about the EDR – Effluent Direct Reuse

Not covered here? Ask an engineer on WhatsApp.

Where does EDR work best?

EDR is designed for coloured, high-solids effluent such as textile, denim and pigment wastewater, where conventional primary treatment uses a lot of chemicals and produces a lot of sludge.